Hip replacement is a surgical procedure in which the hip joint replaced by a prosthetic implant. They can perform it as a total replacement or a Hemi (half) replacement. This surgery relieves arthritis pain or fixes the severe physical joint damage as part of hip fracture treatment.
A total hip replacement (total hip arthroplasty) comprises replacing both the acetabulum and the femoral head while hemiarthroplasty only replaces the femoral head.
Hip replacement is a successful and reliable orthopedic operation. The improved outcome is 97%.
We use DePuy (J &J), Exactech (USA), Zimmer implants.
Sometimes we use Indigenous implants.
The Acetabular cup is the component it places into the acetabulum (hip socket). it attaches which using friction or cement.
Some acetabular cups are one piece, others are modular. One piece (monobloc) shells are polyethylene or metal. They have their articular surface machined on the inside surface of the cup and do not rely on a locking mechanism to hold a liner in place.
A monobloc polyethylene cup is cemented in place while it holds a metal cup in place by a metal coating on the outside of the cup.
Modular cups comprise two pieces, a shell, and liner. It makes the shell of metal; the outside has a porous coating while the inside contains a locking mechanism designed to accept a liner.
The femoral component is the component that fits in the femur (thigh bone).
There are two types of fixation, cemented and uncemented.
They use acrylic bone cement to form a mantle between the stem and to the bone.
Modular components comprise different head dimension and/or modular neck orientations, these attach via a Morse taper. These options allow for variability in leg length, offset and version. It makes femoral heads of metal or ceramic.
It machines metal heads, made of cobalt chromium for hardness to size and then polished to reduce their coefficient of friction and minimize the wear they generate.
Ceramics heads have a lower coefficient of friction than cobalt chrome however they are more brittle.
The particular interface is not part of either implant, rather it is the area between the acetabular cup and femoral component.
The particular interface of the hip is a simple ball and socket joint. Size, it can select material properties and machining tolerances at the articular interface based on patient demand to optimize implant function and longevity while mitigating associated risks.
The interface size measured by the outside diameter the head or the inside diameter of the socket.
Different combinations of material have different physical properties it can couple which reduce the amount of wear debris generated by friction.